High-Current Arc Ignition Test is necessary because insulating materials might withstand normal current but fail when a high current accidentally passes. Based on the time to fail up to 300 seconds, UL 746 A categorizes the insulating material.
Features:
1.Designed to comply with the requirements of UL 746A and IEC 60947 - 1
2. Material of the products can be checked by continuous cycle by passing high current through the materials.
3. Panel works in two mode such as Set Mode and Test Mode.
4. Siemens make LOGO PLC to control the test sequence in Test Mode.
5. Test chamber with Safety Interlock Switch.
6.Emergency OFF provision.
7.Protection
for Over Load Trip function when set mode is selected for 10 Sec.
Specifications:
1.
Input Supply : 230V AC, 50 Hz, 40A max. (tailored to your standard
supply from electrical utility)
2. The
adjustable current source is 230V AC @ 40AMP.
3. Power Consumption peak during arcing
is 9.2 kW
4.
Measurement accuracy (current) is 1%
5. The
load is adjusted to get 33.0 A at 0.5
Power factor across the DUT using
Variac.
6.
Dimensions (H*W*D) : 900mm * 600mm *
680mm