Pharmaceutical water systems are vital to the pharmaceutical industry, not only to protect equipment and instruments, but also to ensure the safety of medicines and thus the health of patients. Our highly efficient purified water system can effectively remove microbial pathogens, organic matter and medium to high molecular weight ions.
Applications of Pharmaceutical Water System
Formulation & Production: Serves as the primary ingredient water for injectables (water for injection), vaccines, biologics, and ophthalmics where endotoxin control is paramount.
Equipment & Component Cleaning: Provides high-purity water for Cleaning-in-Place (CIP) and final rinsing of vessels, piping, and primary packaging to prevent contamination.
Laboratory & Quality Control: Supplies ultra-pure analytical grade water for critical testing (HPLC, GC-MS, microbial assays) in QC and R&D laboratories.
Utilities & Support Systems: Feeds pure steam generators for sterilization processes and cleanroom humidification systems.
Benefits of Our Ultrapure Water Systems
Microbial Pathogen Removal: Our pharmaceutical water systems utilize advanced purification techniques to eliminate microbial pathogens effectively. This process is crucial because even low levels of contaminants can lead to significant risks in drug manufacturing. The system employs multi-stage filtration, UV sterilization, and reverse osmosis processes designed to ensure that water used in pharmaceutical applications is free from any harmful microorganisms.
Elimination of Organic Contaminants: Our systems are engineered to remove not only microbial contaminants but also organic substances. Organic impurities can originate from raw materials, atmospheric conditions, or other external factors. Our water purification systems integrate specialized absorption methods and advanced filtration systems to ensure that water remains pure and compliant with industry regulations.
Spcification
SKSS-RO/EDI-0.25T Ultra-pure water equipment | |||
Equipment external dimensions | (2100mm/700mm/1700mm) | ||
Equipment treatment process | Raw water - Raw water pump - Mechanical filter - Activated carbon filter - Add scale inhibitor | ||
Control mode | Fully automatic operation | Equipment power supply | AC/380V/50HZ |
Raw water pump | Q=2m³/H | Primary High Pressure Pumps | Q=1m³/H |
Secondary high pressure pump | Q=1m³/H | Reverse osmosis membrane vessel | 1 pole 4 inches |
EDI booster pump | Q=1m³/H | EDI module | 250L/H |
Quartz sand filter | φ250×1400mm | Activated carbon filter | φ250×1400mm |
Precision filter | 5 pole 10 inch | Precision Filter | 10 inches 5 microns |
Scale / PH dosing pump | Q=1L/H | Scale inhibitor/PH dosing tank | 40L |
Primary reverse osmosis membrane | 4040 | Secondary reverse osmosis membrane model | 40 |