HF series on off grid hybrid solar inverter

Category

Electrical Equipment & Supplies

Sub-Category

Solar Cells, Solar Panel

Completed orders

0

Price

$400.00

Delivery Cost

$9999.00

Minimum Order

5 pieces

Location

Floor 8, Unit 1, Building 1, No. 3 Jinhang Middle Road, Shunyi District, Beijing, , ,

Adopting high-frequency design, high power density, small size and high overall efficiency; Bidirectional energy storage design can realize bidirectional flow control of electric energy, and both photovoltaic and mains power can charge the battery;

Product Attributes

Adopting high-frequency design, high power density, small size and high overall efficiency;

Bidirectional energy storage design can realize bidirectional flow control of electric energy, and both photovoltaic and mains power can charge the battery;

Ultra-wide MPPT range, as low as 80Vdc;

The working mode can be set (on-grid mode, off-grid mode, hybrid mode);

Equipped with output priority setting function;

With charging priority setting function;

Equipped with lithium battery BMS communication function;

Support battery-less operation mode;

Supports the use of smart meters to prevent back flow when running on the grid.

Technical Parameters

Off-Grid Operation (AC Input)

Rated input Voltage:220V/230V/240V

Mains Input Voltage Range:165Vac~280Vac/120Vac~280Vac(can be set)

Rated Input Frequency:50Hz/60Hz

Input Frequency Range:45Hz~55Hz(50Hz),55Hz~65Hz(60Hz)


Mixed Operation (Complementary Mode (AC Input))

Rated Input Voltage:220V/230V/240V

Mains Input Voltage Range:187Vac~264Vac

Rated Input Frequency:50Hz /60Hz

Input Frequency Range:47Hz~52Hz(50Hz),57Hz~62Hz(60Hz)


General parameters

Maximum Conversion Efficiency(Battery Discharge):94%(peak)

Mppt Tracking Efficiency:≥99.9

Conversion Time:10mS (Typical value)

Panel Display:LCD+LED

Heat Dissipation Method:Smart fan control

Communication Function:RS485/dry contact/mobile phone APP (WlFl monitoring or GPRS monitoring) (optional)

Protection Level:IP20

Installation Method:Wall-mounted


Protect

Battery Low Voltage Alarm:44Vdc (default)

Battery Undervoltage Protection:42Vdc (default)

Anti-lslanding Protection:≤2S

Overload Power Protection:Automatic protection (battery mode), circuit breaker or fuse (mains mode)

Output Short Circuit Protection:Automatic protection (battery mode), circuit breaker or fuse (mains mode)

Over Temperature Protection:>90°C(turn offinverter and charging)


Environment

Operating Temperature:-10C~50°C

Storage Temperature:-15C~60°C

Noise:≤55dB

Altitude:2000m(If it exceeds the limit, derating is required)

Relative Humidity:0%~95%,no condensation



Company Rating
Img

Overall Rating

Description Rating

Delivery time

Contact

Professionalism